Wiegand Distance, Ground the Drain-wire at one end only - at the DRM Board (GND).
Wiegand Distance, 08 VDC at that distance. Wiegand is a proprietary information coding format used for encoding access cards, key tags, proximity readers, and other access control related products and devices. It's a 3 wire serial, running at 5V to achieve distance. The Wiegand interface uses three wires, one of which is a common ground and two of which are data transmission wires usually called DATA0 and DATA1, alternately labeled "D0" and "D1" or "Data Low" and "Data Wiegand or Multi-Discipline Reader Distance CAUTION: When implementing the 150 m (164 yd) cable distances with Impro Wiegand Readers use the 12 V power output option. It can work Wiegand and OSDP comparison guide Save as PDF Table of contents Wiegand and OSDP comparison OSDP supported features For decades, the Wiegand interface served as the industry standard for Access Control wiring. Do not connect the HID Proximity ThinLine II 5395 Providing performance and reliability, HID's attractive, unobtrusive ThinLine II proximity card reader is housed in a two-piece, weatherproof secure potted enclosure. Both the shield and the GND wire can share the same GND terminal. Apr 28, 2026 · Recommended maximum cable length: 300 ft (91 m) with CAT6 or 500 ft (152 m) if two wire pairs are used for GND and VIN (power). Most card reader manufacturers publish a maximum cable run of 500 feet (150 m). This is the most common protocol today to deliver credentials from a reader to an Access Control Panel. 1. com Larger conductors are recommended as distance increases to minimize voltage drop and maintain signal quality. The wiegand pair might not work at this 425 feet distance though- the spec for wiegand using 22 AWG non-twisted shielded copper wire is about 250 feet. 0 Wiegand Reader - Cable Specs & Wiring 5-conductor, 22 AWG, overall shielded; max cable distance is 500 feet. Table 1. S. Feb 5, 2014 · The theoretical limit for Wiegand signal wire to a reader from the panel is 500 feet assuming you are using an 18 AWG shielded, excellent quality cable in a noise-free environment. Twisted pair cables such as Cat5e or Cat6 are not typically recommended for Wiegand applications, as twisting of the data lines can introduce signal irregularities. Ground the Drain-wire at one end only - at the DRM Board (GND). Maximum wiring distance for Wiegand Wiring gauge Maximum distance from reader to controller 18 AWG 300 ft (91 m) 20 AWG 300 ft (91 m) 22 AWG 200 ft (61 m) 24 AWG 200 ft (61 m) Dec 1, 2022 · Typically, Wiegand technology is found in cards, fingerprint readers, or any other data-capturing devices. If you use 22 AWG, that distance drops dramatically to 250 feet. See full list on galaxysys. The maximum distance between a control panel to a reader is 150 meters. What is Wiegand output? How far can you run access control Cable? Credential readers must be within a 500-foot distance from the ACU for the reader to work properly. Base part numbers: 5395 (Wiegand), 5398 (Clock-and The transmitter with standard WIEGAND readers widely used in access control systems. wjvs, kgf, xmqma7, ae1zl1uv, ksz, e4mi, jgn, ln, yovni2x, snt, \